H2O2 Analyzer - G2114
The Picarro G2114 gas concentration analyzer offers continuous, real-time H2O2 monitoring by measuring hydrogen peroxide levels as low as 3 ppb. The G2114 is the ideal solution for ensuring the safety and efficiency of whole-room decontamination technologies based on hydrogen peroxide.
Isotopic N2O Analyzer - G5102-i
The Picarro G5102-i isotopic and gas concentration analyzer enables measurements of site specific and bulk δ15N in N2O. It is an ideal solution for discerning and measuring the source of N2O emissions real-time in the field or through grab-sample measurements in the lab. The isotopomers of N2O can be used to probe sources and sinks in the global nitrogen cycle by identifying nitrification and denitrification processes in soils and water.
Autosampler - A0325
Picarro Autosampler - Automatically draws water from 2mL vials and delivers from 1uL to 10uL of water into your vaporization unit of choice.
G2205 Analyzer User Manual for HF
The Picarro G2205 gas concentration analyzer provides precise, real-time measurement of hydrogen fluoride (HF) and water (H2O) vapor at parts-per-trillion (ppt) sensitivity with negligible drift for atmospheric science and air quality applications. This manual provides safety, contents, overview, installation, operation, log messages, file management, calibration, troubleshooting, maintenance, remote data access, data file viewer, and external valve sequencer information.
CH4 and C2H2 Analyzer - G2203
The Picarro G2203 gas concentration analyzer provides simultaneous, precise measurement of methane (CH4) and acetylene (C2H2) at parts-per-billion (ppb) sensitivity with negligible drift for measuring fugitive emissions of CH4 from landfills, or other extended CH4 sources, using a C2H2tracer measurement for quantifiable emission rates.
O2 Analyzer - G2207-i
The Picarro G2207-i gas concentration and isotope analyzer combines high precision and low drift O2 concentration measurement with δ18O analysis in ambient air. This makes it ideal for challenging applications including atmospheric oxygen monitoring to identify the biogeochemical process involved in the carbon cycle.
PI2114 Analyzer User Manual (H2O2)
Measures hydrogen peroxide levels as low as 3 ppb to help avoid oxidation and safeguard drug stability. Major pharmaceutical, CMO, and isolator companies use Picarro hydrogen peroxide analyzers in high-potency API and biologics manufacturing and in aseptic fill and finish. The PI2114 analyzer is fast and easy to use. It doesn’t need chemicals or consumables. It requires infrequent calibration and maintenance to minimize operating costs.
Isotopic Water Analyzer - L2120-i, L2130-i, L2140-i
δ18O and δD Analyzer. Isotope measurements from liquid and vapor water samples.
G5310 Analyzer User Manual (N2O, CO, and H2O)
This manual provides safety, contents, overview, installation, operation, GUI functions, log messages, file management, calibration, troubleshooting, maintenance, storage, remote data access, data file viewer parameters, analog signal output, and external valve sequencer information.
N2O Analyzer - G5131-i
Identify N2O sources and sinks or illuminate nitrification and denitrification processes. With N2O as the next frontier in greenhouse gas measurements, take your science to the action with high quality data from the Picarro mid-infrared platform.
G4302 Analyzer User Manual (CH4 and C2H)
This manual provides safety, components, battery and filter installation, storage and transport, reading and monitoring, mode switching, shutdown, GUI functions, file management, data file viewer, calibration, maintenance, and parameter information.
CO2 and CH4 Analyzer - G4301
A new-generation, light-weight, portable, battery-powered cavity ring-down spectroscopy (CRDS) gas concentration analyzer designed for science on the move.
G2401-m Analyzer User Manual for O2, CO, CH4 and H2O
Picarro CRDS analyzer for gas concentration measurements of the four primary greenhouse gases during flight or airborne sampling. This manual provides safety, contents, overview, installation, operation, GUI functions, file management, calibration, troubleshooting, maintenance, remote data access, data file viewer, and external valve sequencer information.
G2401 User Manual (EN) for CO, CO2, CH4, and H2O
Simultaneous, precise measurement of CO2, CH4, and H2O for lab, field or mobile applications. This manual provides safety, contents, overview, installation, operation, GUI functions, file management, calibration, troubleshooting, maintenance, remote data access, data file viewer, and external valve sequencer information.
CO2, CH4, and H2O Analyzer - G2311-f
Measure CO2, CH4 and H2O in a single instrument at 10 Hz or 0.2 Hz for eddy covariance, gradient, eddy accumulation and other methodologies.
G2307 Analyzer User Manual for H2CO
This manual provides safety, contents, overview, installation, operation, Gui functions, file management, calibration, troubleshooting, service and maintenance, storage, remote data access, data file viewer, external valve sequencer, and data log parameters information.
G2301 Gas Concentration Analyzer User Manual for CO2/CH4/H2O
Picarro CRDS analyzer for the gas concentration of the primary greenhouse gases in ambient air. This manual provides safety, contents, overview, installation, operation, log messages, GUI functions, file management, calibration, troubleshooting, maintenance, remote data access, data file viewer, and external valve sequencer information.
G2210-i Analyzer User Manual for C2H6-to-CH4
Designed to address the scientific community’s need for real-time methane emissions source attribution. High-precision atmospheric methane and ethane measurement capabilities, combined with carbon dioxide and water vapor measurements, provide the user with a unique tool to measure and determine the source of methane emissions—including landfills, fracking sites and abandoned oil and gas wells.
G2204 Analyzer User Manual for H2S and CH4
The Picarro G2204 gas concentration analyzer provides simultaneous, precise measurement of methane (CH4) and hydrogen sulfide (H2S) at parts-per-billion (ppb) sensitivity with negligible drift for emissions measurements from landfills, refineries, paper mills, or industrial plants.
G2201-i Analyzer User Manual for Isotopic CO2 / CH4
G2201-i Analyzer User Manual for Isotopic CO2 / CH4 provides safety, overview, installation, operation, log messages, measurement modes, coordinator tool, GUI functions, file management calibration, best practices, service, and maintenance.
G2131-i Analyzer User Manual for Isotopic CO2
G2131-i Analyzer User Manual for Isotopic CO2 provides safety, packing, overview, installation, operation, log messages, GUI functions, file management, calibration, CRDS controller, troubleshooting, and maintenance.
G2108 HCl Analyzer User Manual
The Picarro G2108 Hydrogen Chloride Analyzer is a real-time, trace gas monitor capable of measuring HCl with parts-per-trillion (ppt) sensitivity. This manual provides an overview, installation, operation, GUI functions, file management, calibration, troubleshooting, and maintenance.
Small Sample Introduction Module - A0312
Enables collection of very small gas samples (20ml) for gas concentration and gas isotope concentration measurements using Picarro CRDS analyzers.
A0301 Liaison Universal Interface User Manual
Extends Picarro isotopic CO2 analysis to virtually any elemental analyzer. Fully automated for high throughput. Installs in minutes.
Micro-Combustion Module (MCM) - A0214
The Micro-Combustion Module™ (MCM) includes Picarro's unique Micro-Combustion Technology for catalytic oxidation. This in-line process oxidizes organic compounds in samples, eliminating spectral interferences and enhancing analyzer performance.
Induction Module (IM) - A0213
Extracts water from samples such as soil, plants, tissues or juices and enables isotopic analysis of the extracted water.
High-Precision Vaporizer - A0211
An auxiliary module that is controlled by the Picarro water stable isotope analyzer, L2130-i or L2140-i.
Standards Delivery Module for Field Isotopic Water Applications - A0101
System to deliver liquid water standards for calibration of isotopic water measurements in situ using Picarro CRDS analyzers.
Combustion Module for CM-CRDS BSIA Analysis of Isotopic CO2
Combustion Module for use with Picarro's CM-CRDS system for bulk stable isotope analysis of isotopic CO2.
AN041 - Field Deployment of Picarro G2508 and Eosense eosAC/eosMX in Perennially or Periodically Flooded Soils
Flood-irrigated agricultural soils can be a significant source of the greenhouse gases (GHG) carbon dioxide (CO2), methane (CH4), and nitrous oxide (N2O) (Linquist et al. 2011, Oertel et al. 2016). As these ecosystems are typically characterized by high spatial and temporal heterogeneity, continuous trace gas measurements are needed to better detect patterns and quantify net ecosystem fluxes.
G2121-i Analyzer Datasheet
G2207-i Analyzer Datasheet
G5131-i Analyzer Datasheet
G2132-i Analyzer Datasheet
G2106 Analyzer Datasheet
G2205 Analyzer Datasheet
G2108 Analyzer Datasheet
G2308 Analyzer Datasheet
G2203 Analyzer Datasheet